  1. Short:    V3.1 Microtek/Highscreen/Mustek scanner driver
  2. Author:   wzoehner@nuernberg.netsurf.de
  3. Uploader: wzoehner@nuernberg.netsurf.de
  4. Version:  3.1
  5. Type:     hard/drivr
  6.  
  7.  
  8.                         ScanTek 3.1
  9.  
  10.                     A scanner driver for
  11.                Microtek, Highscreen and Mustek
  12.                       Flatbed Scanner
  13.  
  14.  
  15.             © Copyright 1995/96/97 Waldemar Zöhner
  16.  
  17.                   Get It, Feel It, Love It
  18.  
  19.  
  20.  Overview
  21. ----------
  22.  
  23.  The ScanTek scanner driver has the following features:
  24.  
  25.  1. Support of the following SCSI Microtek scanner models:
  26.         MICROTEK IISP, MICROTEK II, HIGHSCREEN Flatbed Color IIs,
  27.         ScanMaker E3, ScanMaker 35t, ScanMaker E6
  28.  
  29.     Support of the following SCSI Mustek scanner models:
  30.         Three Pass Scanners:
  31.         6000CX, 8000CX (not tested), 12000CX (not tested) all should work
  32.  
  33.         One or Single Pass Scanners:
  34.         6000SP, 8000SP (not tested), 12000SP (not tested) all should work
  35.         6000CZ (not tested), 8000CZ (not tested)
  36.  
  37.         600IISP, 800IISP (not tested) all should work
  38.  
  39.     If your scanner is not mentioned in the list above try it and
  40.     give me a response whether it works or not.
  41.  
  42.     Attention: In recent times Mustek has changed the scanner firmware.
  43.                I urge you to test Mustek scanners with your Amiga
  44.                configuration before buying it.
  45.  
  46.                Mustek scanners have a critical SCSI interface. It
  47.                was reported to me that these scanners may not work
  48.                with the A3000(T) internal SCSI interface. It is
  49.                possible that these scanners do not work with other
  50.                SCSI host adapters, either.
  51.                But the Mustek 6000CX works in combination with an
  52.                Oktagon SCSI host adapter.
  53.                Be sure to disable reselection for Mustek scanners
  54.                on your SCSI host adapter. Otherwise your system may
  55.                not boot.
  56.  
  57.  
  58.  2. Support of black/white, built-in halftone (dither), one-pass-color-scan,
  59.     three pass color scan, grey, red, green and blue scan.
  60.  
  61.  3. Individual setting of resolution, scanning frame, contrast, shadow,
  62.     midtone, highlight, exposure time and scanning speed for download to the
  63.     scanner.
  64.  
  65.  4. Download of a color look up table (gamma correction table ) to the scanner
  66.     supported.
  67.  
  68.  5. Scanning to IFF File of 1, 8 or 24 bit color depth. The maximum size of
  69.     the scanned image is independent from the RAM size. After the scanning
  70.     process it is possible to start an external program.
  71.  
  72.  6. GUI for preview and configuration of the driver. You need Kickstart 2.04
  73.     but Kickstart 3.0 is recommended.
  74.  
  75.  7. Sizeable preview window in black/white or grey scale. Color preview
  76.     on Cybergraphix screens (15, 16 or 24 bit necessary).
  77.     There are much more skilled programs to view and manipulate the scanned
  78.     images in color. (A tool like ADPRO, IMAGE FX or so is needed, if you
  79.     want to do sophisticated postproduction)
  80.  
  81.  8. ARexx support
  82.  
  83.  9. Screenmode requester to define custom screen for working. The actual public
  84.     screen is supported as well
  85.  
  86.  10. Configurable SCSI device and SCSI ID. The driver supports only SCSI
  87.      connectable scanners.
  88.  
  89.  11. The driver is tested with the following SCSI drivers: oktagon.device and
  90.      gvpscsi.device V4.5.
  91.  
  92.  12. ScanTek is written using SAS C 6.55.
  93.  
  94.  13. ScanTek is SHAREWARE.
  95.  
  96.  14. The non registered version of ScanTek is a full working version, but all
  97.      scanned images have black lines to motivate you to register.
  98.      Additionally the maximum size of the preview is restricted.
  99.  
  100.  
  101.  History
  102. ---------
  103.  
  104.  V3.1   19 May 1997
  105.  
  106.    - Recognition of Highscreen PerfectScan (600dpi) introduced
  107.  
  108.    - Recognition of Highscreen RealScan (300dpi) introduced
  109.  
  110.    - Activation of newly opened windows works now correct
  111.  
  112.  
  113.  V3.0   16 Apr. 1997
  114.  
  115.    - AREXX support
  116.    - XBMI-chunk introduced to store DPI (dots per inch) information in
  117.      IFF File
  118.    - Handling of Microtek ScanMaker E6 enhanced
  119.    - Bugfixes: "Exposure Time" and "Contrast" parameters for Microtek
  120.                and some Mustek scanner models are now correct.
  121.                This bug could lead to images that where to light.
  122.                Grey preview of color image now work with all specified
  123.                settings.
  124.  
  125.  
  126.  V2.10 26 Mar. 1997
  127.  
  128.    - Full size preview on 400 dpi Mustek scanners adjustable
  129.  
  130.  
  131.  V2.9   9 Feb. 1997
  132.  
  133.    - Look Up Table Window redesigned to ensure font sensitivity
  134.  
  135.  
  136.  V2.8  11 Jan. 1997
  137.  
  138.    - New icons for ScanTek
  139.    - Recognition and handling of new Mustek scanners enhanced
  140.    - Minior bug fixes
  141.    - Introduction of the ScanTek Support WebSite
  142.  
  143.  
  144.  V2.7  6 Dec. 1996
  145.  
  146.    - Recognition and handling of new Mustek scanners enhanced
  147.    - Recognition of Microtek ScanMaker E6 adapted
  148.  
  149.  
  150.  V2.6  30 Oct. 1996
  151.  
  152.    - Full support of Mustek one pass scanners
  153.    - Recognition of Mustek scanners enhanced
  154.  
  155.  
  156.  V2.5  5 Oct. 1996
  157.  
  158.    - Workaround to handle strange color mode behaviour of Mustek
  159.      one pass scanners
  160.    - Reverse scanning in black and white mode introduced
  161.  
  162.  
  163.  V2.4 10 Sept. 1996
  164.  
  165.    - Support of Mustek SCSI one pass color scanners in color mode and
  166.      parameter ranges.
  167.    - ScanTek can now open its GUI windows on the actual public screen.
  168.  
  169.  
  170.  V2.3  6 Sept. 1996
  171.  
  172.    - Color Preview on Cybergraphix screens in true color mode
  173.      (15, 16 or 24 bit) for onepass flatbed scanners
  174.    - Grey/Red/Green/Blue Preview on Cybergraphix screens in true color mode
  175.      (15, 16 or 24 bit) for threepass and onepass flatbed scanners
  176.    - Change and recall of predefined resolution values
  177.  
  178.  
  179.  V2.2 26 July 1996
  180.  
  181.    - Enhanced support for Mustek scanners
  182.      "Exposure Time" and "Contrast" parameters are now correct
  183.    - Gamma value "All" now works on threepass scanner
  184.    - Alternative Black/White scanning mode
  185.  
  186.  
  187.  V2.1  5 July 1996
  188.  
  189.    - Preview now fully supported for Mustek 6000CX
  190.    - Special adaption for Mustek 6000CX to use 8.5 * 14 inch scanning frame
  191.  
  192.  
  193.  V2.0  30 Apr. 1996
  194.  
  195.    - Preview in color mode with proper options values
  196.    - Use of expanded Contrast and Exposure Time selections on certain scanners
  197.    - X and Y Aspect Ratio in color images is correct now
  198.    - ScanMaker E3 does not support undocumentated red, gree and blue scanning
  199.    - Lookup Table command supported (Gamma Correction on certain scanner
  200.      possible)
  201.    - Scanning Frame Setting is now more intuitive
  202.    - Reverse image scanning supported (only on certain scanners possible)
  203.    - Accurate scanning supported. Scanning frame is now more precise.
  204.  
  205.  
  206.  V1.3  25 Feb. 1996
  207.  
  208.    - Detection of new ScanMaker E3 Flatbed scanner implemented
  209.    - Special adaption for E3 to use 8.5 * 13.5 inch scanning frame
  210.      (due to E3 inquiry data the max frame size is 8.5 * 11.69 inch)
  211.    - No start of the external program, if the scanning process is aborted
  212.    - Higher dpi rates for ScanMaker 35t (slide scanner) possible
  213.      Preview image should look better now.
  214.    - "Main Control" window and gadgets modified
  215.    - Debug filename "ScanTek.log" can be overriden through CLI or Tooltype
  216.  
  217.  
  218.  V1.2   3 Jan. 1996
  219.  
  220.    - Debug output data revised and enhanced
  221.    - Max Frame Setting setting introduced
  222.    - Start of external program possible
  223.    - Window positions are remembered and saved
  224.    - Configuration file enhanced
  225.  
  226.  
  227.  V1.1  17 Dec. 1995
  228.  
  229.    - detection of Microtek scanner via SCSI inquiry enhanced
  230.    - stepping of resolution slider adapted to expanded base resolution
  231.    - calculation of scanning frame size data modified
  232.  
  233.  
  234.  V1.0  30 Nov. 1995